OBCB_StopB c+ [D>=19]
Stop OBCB counter c in Phase B
Stop counting pulses on counting input c using the OnBoard Counter B (Firmware) counter. Counting will stop when the OBCB time base is in phase B. If the time base is in phase B when the instruction is executed, counting stops at once. If it is in phase A, counting will stop when it next enters phase B.
OBCB provides a medium speed counting feature on multiple inputs of selected controllers. Please refer to specific controller documentation for details as well as OBCB generic documentation.
+ The channel argument will be jndexed when executed inside a MultiTrack task and will be indexed if the instruction is preceded by the IasJ: precode.
Dialect exclusions: Not available in dialects before 19.
Note: At time of writing there is no simulation of the OBCA in SPLat/PC
See also: OBCB_GoIfA, OBCB_GoIfB, OBCB_Start, OBCB_StartA, OBCB_Stop, OBCB_fRead, OBCB_fRdClr
Alternative counter mechanisms: OnBoard Counter A, OnBoard Quadrature Counter