SX10507 Demo: What You Will Need
You will need the following to test and demonstrate the SX10507:
- Mmi202aDK216 SPLat controller board with at least version 3.22 Firmware loaded
- The latest pHDemo.spt source file
- SX10507 Xwire pH peripheral expansion board
- pH probe with a BNC connector as termination for the pH probe
- TTL Xwire cable (2 wire for use over short distances)
- DC power supply, 12 or 24 Volts, 200mA or greater
- pH 7 buffer solution
- pH 4 buffer solution
- Distilled water
- Optional - PT1000 RTD sensor, stand alone or built into the pH probe
- Optional - 2K to 10K thermistor, stand alone or built into the pH probe **
** Note: If a thermistor is used, the demonstration program will require the linearising polynomial to be updated with the correct coefficients for the chosen thermistor. See: Tutorial: Thermistor temperature measurement