OBCB_fRdClr c [D>=19]

Read OnBoard Counter B (Firmware) counter channel c to W as a floating point number, then clear the counter.

OBCB provides a medium speed counting feature on multiple inputs of selected controllers. Please refer to specific controller documentation for details as well as OBCB generic documentation.

Dialect exclusions: Not available in dialects before 19.

Note: At time of writing there is no simulation of the OBCA in SPLat/PC

See also: OBCB_GoIfA, OBCB_GoIfB, OBCB_Start, OBCB_StartA, OBCB_Stop, OBCB_StopB, OBCB_fRead

Alternative counter mechanisms: OnBoard Counter A, OnBoard Quadrature Counter